National Instruments SCXI-1303 Isothermal Terminal Block. Measure™ Data Acquisition. are not included with this equipment unless listed in the above stock item description. National Instruments Senior Applications Engineer National Instruments PXI-8421/8 8-Port RS485 Interface Card $ 109. All prices are shown in USD. SCXI-1303 Front Connector Pin Assignments SCXI-1303 Terminal Block Calibration Procedure ni. 884. This terminal block is an ideal solution for large-channel-count temperature or voltage applications. Create an Account. 10-14-2015 09:46 AM. National Instruments SCXI-1129 with electromechanical relays. If you need a specific firmware or series relating to SCXI-1300, we probably have it. To check the compatibility between the driver version and the LabVIEW version, see the Compatibility Table. The main function of the NI SCXI-1303 is to connect the SCXI-1100 and SCXI-1102/B/C through block terminals. Mark as New;. Part Number: 187254A-01. Part Numbers: 184642B-01, 184642C-01, 184345D-01, 184345E-01, 776572-26. Part Number: 186336B-01, 777966-40. Academic and Research. The SCXI kit connects a switch controller to an SCXI switch module; the USB kit connects a computer to an SCXI switch module. Every channel has a configurable lowpass filter of 4. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. SCXI-1129. Applications Engineer National Instruments . The NI TBX 1303 has free UPS ground shipping and a warranty. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. This module is a full-featured control and data module for SCXI digital I/O, switching, analog input, and analog output modules. All prices. 500 MHz, 32-Channel RF Multiplexer Switch Module for SCXI —The SCXI‑1193 is a high-density RF relay module. Ensure the DAQ (Data AQuisition) device used to connect to SCXI Chassis is recognized by NI-MAX and self-test has passed succesfully. Order international: +1 609. SCXI™ Getting Started with SCXI. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。system, National Instruments provides no-cost standard technical support via e-mail and phone for all registered users on all products. Downloadable Technical Manuals and Datasheets. It's being used. Get a quote for a Used SCXI 1303 Miscellaneous Test Equipment from Apex Waves, LLC at used-line. If you look in the SCXI-1303 Installation Guide, you will see that there are four banks of these resistors. It has a cold-junction compensation sensor for temperature measurements and multiple gain ranges with a 2 Hz cut-off frequency filter. Support Worldwide Technical Support and Product Information ni. 2. com. Order international: +1 609. com 327 SCXITerminal Blocks Data Acquisition andThanks. are not included with this equipment unless listed in the above stock item description. Re: scxi-1300/scxi-1303 andrew_JKTA. National Instruments recommends that you replace the factory installed 10 MΩ bias resistor networks of the SCXI-1303 with the 10Ω resistors supplied with the kit. Work with our experts to sustain your critical applications. The SCXI-1104/C modules are members of the National Instruments Signal Conditioning eXtensions for Instrumentation (SCXI) Series that are designed for use with National Instruments data acquisition (DAQ) devices. 51 or later Flathead screwdriver Number 1. are not included with this. are not included with this equipment unless listed in the above stock item description. View and Download National Instruments SCXI-1000 quick start manual online. The SCXI-1102B (Part Number: 776572-02B) has a three-pole lowpass filter with a 200 Hz cutoff frequency, 32 differential channels, and DC input coupling. To set up and use your SCXI-1326 terminal block kit, you need the following components: SCXI-1326 High-Voltage Terminal Block Installation Guide SCXI-1326 high-voltage terminal block SCXI chassis SCXI-1162, SCXI-1163, SCXI-1162HV, or SCXI-1163R module Number 1 and 2 Phillips-head screwdrivers 1/10 in. DISCONTINUED BY. Industry leading, price advantage, quality assurance 3. Price: Contact a sales representative. com ¥ ni. Start»All Programs»National Instruments»NI-DAQmx after installing NI-DAQmx. This has two High Voltage Analog Bus (HVAB) ports. I have read the article detailing how to remove the pullup and bias resistors to enable thermistor/RTD measurements on the 1303. com 8-Channel Strain/Bridge Input Module for SCXI —The SCXI‑1520 is a strain/bridge input module. SCXI 1303 32 CHANNEL ISOTHERMAL TERMINAL BLOCK INSTALLATION. Expand the chassis where the SCXI-1600 module is located. The PXI-1052 complies with the PXI Hardware Specification, Revision 2. Here, there are few details about my systems. Trusted Supplier for Industrial & Military. The kit offers multi-position capability for both recessed and flush mounting. Regards, h_baker National Instruments Applications Engineer Digital Multimeter Resources. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100SCXI-MS100 Temperature Measurement System 2 SCXI-1000 chassis with AC power cord SCXI-1102 module SCXI-1303 terminal block SCXI-1349 cable assembly (cable and cable adapter) NI-DAQ driver software on CD-ROM, version 6. Thank you, -TomThis document explains how to install and configure SCXI signal conditioning modules in SCXI-1000, SCXI-1001, SCXI-1000DC, or PXI/SCXI combination chassis, confirm the module and chassis are. SCXI-MS100 Temperature Measurement System 2 SCXI-1000 chassis with AC power cord SCXI-1102 module SCXI-1303 terminal block SCXI-1349 cable assembly (cable and cable adapter) NI-DAQ driver software on CD-ROM, version 6. Price: Contact a sales representative for a quote. SCXI Terminal Blocks Overview National Instruments SCXI terminal blocks provide a convenient. 2. com or CALL 800 813 3693 (U. The SCXI-1303 also includes circuitry for open-thermocouple detection as well as automatic ground referencing for floating (nongrounded) thermocouples. BackNational Instruments SCXI-1313 High-Voltage Attenuator Terminal Block. National Instruments recommends that you replace the factory installed 10 MΩ bias resistor networks of the SCXI-1303 with the 10Ω resistors supplied with the kit. Find National Instruments for sale on Machinio. I have a SCXI 1303 front end module connected to a SCXI-1102 . . Expand the NI-DAQmx SCXI Chassis section and choose your chassis model and click Finish. The National Instruments SCXI products were discontinued on September 28 th, 2018. SCXI-1310 Connector and Shell Assembly Figure 2. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Page 2 Sweden 08 587 895 00, Switzerland. The SCXI-1303 has a high-accuracy thermistor, cold-junction temperature sensor, and an isothermal copper plane to. Featured with a 16-bit ADC, the NI SCXI-1600 (Part Number: 776572-1600) is a USB Data Acquisition Module (DAQ) for SCXI. Worldwide Technical Support and Product Information. The NI SCXI-1102C (Part Number: 776572-02C) module has a three-pole lowpass filter with a 10 kHz cutoff frequency, 32 differential analog input channels, maximum working voltage of ±10 V, and a 20 minute suggested warm-up time. SCXI Terminal Blocks National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. Find many great new & used options and get the best deals for National Instruments Ni Scxi-1001 Chassis 12 Slot SCXI Mainframe With 11 Cards at the best online prices at eBay! Free shipping for many products!. ni scxi-1600 scxi-1300 scxi-1303 scxi-1000 机架 端子 NI SCXI-1349库存现货 Company advantage service: 1. SCXI-1303. SCXI-1303. Downloadable Technical Manuals and Datasheets. are not included with this equipment unless listed in the above stock item description. Hi, I have a SCXI-1303, on an SCXI-1102C on an SCXI 1000 chassis. I figured it would be a discrete input but am not sure how it would be read in LabVIEW. This guide describes how to install and use the SCXI-1303 terminal block with SCXI-1102, SCXI-1102B, SCXI-1102C,. com327 SCXI Terminal Blocks Data Acquisition andSCXI-1104, SCXI-1104C, SCXI-1100 _ IC sensor for CJC SCXI-1303 777687-03 Screw terminals Front-mounting SCXI-1102B, SCXI-1102C, SCXI-1100 _ Isothermal construction Pluggable ground referencing. SCXI-1301 National Instruments, NI, SCXI-1301 National Instruments Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United StatesFind many great new & used options and get the best deals for National Instruments NI SCXI-1303 182487B-01 32-Ch. National Instruments SCXI-1127- 30 W, 60 VA maximum switching power for each channel. For information about installing and configuring SCXI modules, refer to the SCXI Quick Start Guide. with screw terminals that connect to the SCXI-1102/B/C and the. Ask for a quote on a Used National Instruments SCXI-1303 Misc. Question: When utilizing a DMM to control a SCXI chassis, which mode can the DMM. National Instruments SCXI-1322 Temperature Sensor Terminal Block. Free Ground Shipping. are not included with this equipment unless listed in the above stock item description. Ships in 5-10 Days. Member Author 07-29-2010 07:16 PM. All prices are shown in USD. You use the SCXI-1181 general-purpose breadboard module to build custom signal conditioning circuitry for analog. are not included with. The maximum update rate is 555 S/s for one channel and 125 S/s per channel for all six channels. All prices are shown in USD. central time. The NI SCXI-1343 is another option which is a general-purpose SCXI adapter with screw terminals. National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation. 0 Help to access the topic. Qty. National Instruments USB-1357 SCXI Plug-and-Play Backplane for USBThis does not include any other equipment or cabling. 5. 8. The SCXI‑1193 module is designed to integrate with high-frequency instr. Fax: (240) 376-1381. Pre-owned: Lowest price. . Member Author 09-14-2007 09:06 AM. SCXI-1129. No. The metallic adapter of this cable is designed to be fastened to the front panel connector of various SCXI modules, including the SCXI-1100, SCXI-1181, SCXI-1102, etc. Phone: (217) 352-9330. The SCXI-1303 has pullup and bias resistors that saturate the channel by applying +5 V at the input of the open channel. Functionally equivalent to the SCXI-1304 terminal block, the SCXI-1305 includes switchable AC coupling circuitry and ground referencing on each. The erractic behavior goes away when I connect the signals to the SCXI 1303. Control Unit National Instruments SCXI SCXI-1102 User Manual (85 pages) I/O Systems National Instruments SCXI-1102 Calibration Procedure. National Instruments Corporate Headquarters 6504 Bridge Point Parkway Austin, Texas 78730-5039 USA Tel: 512 794 0100. This kit is compatible with the SCXI-1001, PXI-1010, and PXI-1011 chassis. National Instruments NI SCXI 1000 1303 1302 1325 1161 1124. 5 /5 based on 6 ratings. National Instruments SCXI is a high-performance signal conditioning and switching platform for measurement and automation systems. 5 to Labview 8. The SCXI-1102 family can read the cold-junction sensorFind many great new & used options and get the best deals for National Instruments NI SCXI-1300 Terminal Block for SCXI Modules at the best online prices at eBay! Free shipping for many products!traces on the SCXI-1303 printed circuit board. All prices are shown in USD. For technical support outside the Americas, please contact your local National Instruments office. 1-800-915-6216 Email: sales@apexwaves. I have recently upgraded from Labview 6. Fax: (240) 376-1381. Dev's suggestion to check for a different output module (or use your DAQ card outputs directly) is what you need to. > (T + 0. Part Numbers: 191141A-01, 777687-17. Of the more than 1,500 PXI products on the market, more than 600 were designed by NI. 99. Part Number: 183087E-02, 183087H-02, 183087K-02L, 183087H-02L. Please call or email us with your request. com today12‑Slot, AC Chassis for SCXI —The SCXI‑1001 is a rugged, low‑noise chassis that powers SCXI modules as well as handles all timing, trigger, and signal routing between other modules and SCXI modules. The National Instruments SCXI-2000 is a 4-slot SCXI chassis powered with standard AC power. S. We offer repair services with a 1 week turnaround and calibration services with a 2 week turnaround. 32-Channel, ±10 V, 2 Hz Filter, Voltage Input Module for SCXI —The SCXI‑1102 is designed for the signal conditioning of thermocouple, millivolt, volt, and current signals. 00. scxi 1001/1102/1303 Fox farmer. com Call Today: 1-800-915-6216 Email: [email protected] SH96-96 is commonly used for connecting SCXI modules to TBX terminal blocks. item 4 NI National Instruments SCXI-1302 Rev2 Terminal Block for SCXI Module 185163A-01 NI National Instruments SCXI-1302 Rev2 Terminal Block for SCXI Module 185163A-01. The bias resistors, and the pull-up resistors were all fitted with the 10Mohm networks. This model comes with a 10 kHz cut-off frequency filter. I have an existing VI that reads 28 k type thermocouples. National Instruments recommends you use the following instruments for verifying your SCXI-1314 terminal block: • Calibrator—Fluke 5700A • DMM—NI 4060 or HP 34401A If these instruments are not available, use the accuracy requirements listed above to select a substitute calibration standard. Several new 1102/1303 pairs were recently added to increase the channel count. The SCXI-1102 also can acquire millivolt, volt, 0 to 20 mA, and 4 to 20 mA current input signals,as well as signals from RTDs when the SCXI-1581 provides excitation. All prices are shown in USD. SCXI-MS100 Temperature Measurement System 2 SCXI-1000 chassis with AC power cord SCXI-1102 module SCXI-1303 terminal block SCXI-1349 cable assembly (cable and cable adapter) Phone: (217) 352-9330. For future expansion or larger systems, up to eight NI SCXI-1000DC Chassis can be daisy. Order toll free: 800. Then, follow the steps below: 1. The 10 MΩ resistors are meant for use with the SCXI-1102/B/C modules, while the 10 Ω resistors are meant. It ships as photoed. This unit uses a DIP switch for chassis addressing. National Instruments SCXI-1600 Data Acquisition Module. Email: National Instruments PXI-1050 8-Slot PXI Chassis With 4-Slots for SCXI | Easy Click-Quote-Buy Today! Fast Shipping. Specifcally I have 8 voltage measurments at 0-10V and 9 pressure measurements at 4-20mA converted to 1-5V signals with a 250ohm resistor. Industry leading, price advantage, quality assurance 3. Part Number: 185365B-02, 185365C-02. Current slide {CURRENT_SLIDE} of {TOTAL_SLIDES}- Save on Terminal Blocks. When the thermocouple channel is open, there is circuitry in. Provides support for NI data acquisition and signal conditioning devices. The NI SCXI-1129 has Free Ground Shipping and a 1-3 Year Warranty. The SCXI-1102, SCXI-1102B, and SCXI-1102C modules are warranted against defects in materials and workmanship for a period of on e year from the date of shipment, as evidenced by receipts or other documentation. Part Number: 182363D-01, 185136B-01, 185136A-01. . If the user wants to utilize the NI SCXI-1104C in a ribbon-cabled multichassis SCXI system. Fax: (240) 376-1381. 1, offering advanced timing and synchronization features. Lab Equipment from EquipNet, Inc. Fax: (240) 376-1381. Your terminal block has the. 9393. Using the old version of labview thermocouple measurements are correct at 0. Installing the TBX-1303 Perform the following steps to mount the SH96-96 cable assembly and connect the TBX-1303 to the SCXI module. SCXI TM SCXI-1102/B/C User Manual SCXI-1102/B/C User Manual April 2006 371975D-01. Page 7 Jumper W1. Price: $179. Re: scxi 1308 noise. Fax: (240) 376-1381. SCXI-1303. Fast Shipping. 0 Kudos Message 4 of 5 (2,364 Views) Reply. For a complete description of. National Instruments SCXI-1128 Matrix/Multiplexer Switch Module- 9 W maximum switching power. TBX-1303 SCXI-1100, SCXI-1102, SCXI-1102B/C, SCXI-1181 SH96-96 or R96-96 Open TC detection Isothermal construction, selectable ground referencing. The SCXI-1124 (Part Number: 776572-24) is a 6-channel isolated Analog Output Module for static DC (low bandwidth) voltage or current signals. Replace x with the corresponding chassis number and y with the corresponding module number. There are eight pairs of s. Also for: Scxi scxi-1102c, Scxi scxi-1102b. Return to Home Page; Toggle navigation; Solutions. All prices. 12 R10 (CH3 Shunt Resistor) 13 W5 (CJC Mode) 14 Warning Label Figure 2. There are switches in the NI SCXI-1327 which allow or disallow the extended input voltage range separately for each channel. Industry leading, price advantage, quality assurance 3. 00 Add to cart; National Instruments SCXI-1000 4-Slot, AC Chassis for SCXI $ 45. Email: National Instruments SCXI-1302 SCXI Terminal Block | Easy Click-Quote-Buy Today! Fast Shipping. National Instruments SCXI-1180. Based on your reply, for a 3 lead RTD, I can connect a jumper and the third wire to the SCXI-1303 on my SCXI-1102B module as shown on pg D-11 of the 1581 manual. This unit ships in the opened National Instruments box. National Instruments SCXI terminal blocks provide a convenient method for connecting and disconnecting signals to your system. The terminal blocks supported are the TBX-1303 and TBX-96. Email: info@artisantg. This unit uses a DIP switch for chassis addressing. Part Number: 776577-70, 182598A-01, 182598B-01, 182598C-01. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100National Instruments 182598-01 Rack Mount Kit. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. ni scxi-1600 scxi-1300 scxi-1303 scxi-1000 机架 端子 NI SCXI-1349库存现货 Company advantage service: 1. National Instruments Corporate Headquarters 6504 Bridge Point Parkway Austin, TX 78730-5039 (512) 794-0100 Technical support fax: (800) 328-2203 (512) 794-5678We have 2 National Instruments SCXI-1303 manuals available for free PDF download: Installation Manual, Operation And Calibration Manual. 00 Add to cart; National Instruments SCXI-1000 4-Slot, AC Chassis for SCXI $ 45. SCXI-1353 Shielded Cable Assembly 2 ni. Diversified models and products, and all kinds of rare and discontinued. SCXI Terminal Blocks National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni. National Instruments developed SCXI signal conditioning products to match the technology, performance, and versatility of our PC-based E Series DAQ hardware. 00 Add to cart; National Instruments SCXI-1303 32-channel isothermal terminal block $ 26. Order international: +1 609. . 5 A 125 V Littelfuse 0251 01. SCXI SCXI-1102 control unit pdf manual download. NI VXI-TB-1303 terminal block; System Requirements Development. 1 or later VirtualBench application software on CD-ROM, version 2. Quick Quotes. The National Instruments SCXI-1308 32-channel current input terminal block is a shielded board with screw terminals that connects to the SCXI-1102/B/C and the SCXI-1100 modules. Over the next few weeks, we will be adding blog posts about the National Instruments SCXI platform. The NI SCXI-1124 incorporates six autonomously isolated, 12-bit digital-to-analog converter (DAC) channels. Fax: (240) 376-1381. National Instruments SCXI-1001 SCXI Chassis. However, all SCXI modules, accessories, chassis, etc. Thus, one of the remaining untested parts of your setup is the cable between the TBX-1303 and the SCXI-1102. Re: scxi 1001/1102/1303 Fox farmer. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Please call or email us with your request. com. The function of the SCXI-1303 is to minimise errors caused by thermogradients whereas the function of the SCXI-1300 is for cold junction compensation. National Instruments: Model: SCXI-1303: Condition: New From Surplus Stock: Product Family: scxi-1303, scxi1303, 777687-03 Find many great new & used options and get the best deals for National Instruments Ni SCXI 1303 32-channel Isothermal Terminal Block at the best online prices at eBay! Free shipping for many products! Waste & Recycling Find out how much to pay for a National Instruments SCXI. Important Information Warranty The media on which you receive National Instruments software are warranted not to fail to execute programmingSCXI-MS100 Temperature Measurement System 2 SCXI-1000 chassis with AC power cord SCXI-1102 module SCXI-1303 terminal block SCXI-1349 cable assembly (cable and cable adapter) NI-DAQ driver software on CD-ROM, version 6. 7 Addendum 2 © National Instruments Corporation Omron. • Seller refurbished condition. The SCXI-1303 is an Isothermal Terminal Block developed by National Instruments. I thought for sure I was trying to order. National Instruments 2-Slot Blank Filler Panel (3U) Configuration: • Length: 5 1/16". 1553. Has been engaged in industrial control industry for a long time, with a large number of inventories. are not included with this equipment unless listed in the above stock item description. Part Numbers: 184826A-01, 184826B-01, 184826C-01, 184826D-01, 184826E-01, 184826F-01, 777570-01. National Instruments SCXI-1313 High-Voltage Attenuator Terminal Block. Experienced Expert Engineers that specialize in your application. The SH96-96 is commonly used for connecting SCXI modules to TBX terminal blocks. This unit includes the power cord. National Instruments SCXI-1303 32-Channel Isothermal Terminal BlockThis item ships sealed in the manufacturer's box. You can shorten this. The SCXI-1308 has thirty-two 249 Ω precision resistors to convert current to voltage when measuring 0–20 mA and 4–20 mA process current sources. SCXI Terminal Blocks National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. This document explains how to install and configure SCXI signal conditioning modules in SCXI-1000, SCXI-1001, SCXI-1000DC, or PXI/SCXI combination chassis, confirm the. ©National Instruments Corporation 3 SCXI-1317 Terminal Block Installation Guide Quarter-Bridge 2- and 3-Wire Strain-Gauge Circuits Note Refer to the Read Me First: Safety and Radio-Frequency Interference document NATIONAL INSTRUMENTS NI-SCXI-1300. Basically I have 3 SCXI1303 with a total of 96 channels and 1 SCXI 1320 with 8 channels. SCXI-1306. Member Author 05-30-2002 11:43 AM. flathead screwdrivers National Instruments SCXI-1102C Voltage Input Module. For technical support outside the Americas, please contact your local National Instruments office. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. NI PXI-1045 PXI-8360 PXI-4060 PXI-4461 PXI-2503 PX. Connects thermocouples and signals to SCXI-1100/ SCXI-1102 Modules. See details for delivery est. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100I have an SCXI-1000, SCXI-1102, and SCXI-1303. Quick Quotes. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100Find many great new & used options and get the best deals for National Instruments SCXI-1303 Isothermal Terminal Block at the best online prices at eBay! Free shipping for many products!The following table lists the fuse information for each National Instruments SCXI chassis: SCXI Chassis Type : Main Power Fuse Quantity : Main Power Fuse Type : Backplane Fuse Quantity : Backplane Fuse Type : SCXI-1000 120 V: 1: 1/2 A 250 V 5 mm X 20 mm SLO-BLO: 2: 1. operating properly, and set up multichassis systems. Work with. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty. All channels are multiplexed with the option of several gain ranges with a jumper-selectable 4 Hz low pass filter. Work with our. Ships in 5-10 Days. If you need a specific firmware or series relating to SCXI-1300, we probably have it. I have read the article detailing how to remove the pullup and bias resistors to enable thermistor/RTD measurements on the 1303. Basically I have 3 SCXI1303 with a total of 96 channels and 1 SCXI 1320 with 8 channels. Data Acquisition Basics Manual LabVIEW Data Acquisition Basics Manual January 2000 Edition Part Number 320997E-01. Any help would be appreciated. 9393. With the 10Ω bias resistors installed in the SCXI-1303, you can measure accurately at the maximum sampling rate of the module, but the open thermocouple channel may not saturate if the问题: 是不是可以用scxi-1102模块和scxi-1303端子板来测量rtd或热敏电阻? 解答: scxi-1581电流激励模块的用户手册上推荐使用scxi. For larger systems, or future expansion, you can also daisy chain up to eight SCXI‑1000DC chassis with a single multifunction I/O dev. Open Start»Programs»National Instruments»NI-DAQ»NI-DAQmx C API Visual Basic 6. Kyle A. National Instruments: Model: SCXI-1303: Condition: New From Surplus Stock: Product Family: scxi-1303, scxi1303, 777687-03SCXI-1303 National Instruments SCXI-1303 32-Channel Isothermal Terminal Block from National Instruments | Buy Today from Artisan. Associated Part Numbers: 181430-01, 181430J. 1553. 0 Kudos Message 4 of 6 (2,770 Views) Reply. 1 or later VirtualBench application software on CD-ROM, version 2. 99. Note National Instruments does not recommend setting jumper W1 on the SCXI-1100 in the non-parking position. 2. 884. 00 shipping. This Terminal Block can additionally extend the threshold level of the SCXI-1126 module from 5 V all the way to 300 V. Support Worldwide Technical Support and Product Information ni. National Instruments 182598-01 SCXI Rack Mount. 5 °C) ≤ T act ≤ (T meas + 0. to 7:00 p. 308 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. Trusted Supplier for Industrial & Military. Fast Shipping. Frequenty Asked Questions. Find many great new & used options and get the best deals for National Instruments Ni SCXI 1303 32-channel Isothermal Terminal Block at the best online prices at eBay! Free shipping for many products!Summary of Contents for National Instruments SCXI-1000. The National Instruments SCXI-1503 is ideally suited for measuring resistive transducers, such as RTDs or thermistors. SCXI-1303. He tried all channels and got the same result. National Instruments SCXI-1303 | In Stock. I have taken a group shot to show that they are all identical, and that you are getting what is pictured. SCXI-1128. TBX-1303 777207-03 Screw terminals 4 SCXI-1102B, SCXI-1102C, SCXI-1104, SCXI-1104C, SCXI-1100 SH96-96 or R96-96 DIN-rail mount. This guide describes how to install and use the SCXI-1300 and SCXI-1301. The SCXI-1102 also can acquire millivolt, volt, 0 to 20 mA, and 4 to 20 mA current input. National Instruments is not liable for any damages or injuries resulting from incorrect signal connections. Using the old version of labview thermocouple measurements are correct at 0. Hello I have a SCXI-1303 Thermo block that I use with a SCXI-1102b module. For larger systems, or future expansion, you can also daisy chain up to eight SCXI‑1000 chassis with a single multifunction I/O device or. 31We also know that the 1102 module is working properly since the SCXI-1303 is working with it. • If (T meas − 0. are not included with this equipment unless listed in the above stock item description. SCXI Terminal Blocks Overview National Instruments SCXI terminal blocks provide a convenient. from national instruments' testing platforms and because a user or application designer may use national instruments products in combination with other products in a manner not evaluated or contemplated by national instruments, the user or application designer is ultimately responsible for verifying and validating the suitability of nationalNational Instruments SCXI-1104C 32-Channel Medium-Voltage Input Module. ©National Instruments Corporation 3 SCXI-1317 Terminal Block Installation Guide Quarter-Bridge 2- and 3-Wire Strain-Gauge Circuits Note Refer to the Read Me First: Safety and Radio-Frequency Interference document before removing equipment covers or connecting or disconnecting any signal wires. National Instruments SCXI-1160 16-Channel General-Purpose Relay Module. com 327 SCXITerminal Blocks Data Acquisition andAsk for a quote on a Used National Instruments NI SCXI-1303 Misc. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100 National Instruments recommends that you replace the factory installed 10 MΩ bias resistor networks of the SCXI-1303 with the 10Ω resistors supplied with the kit. Brian F Applications Engineer National Instruments . Ask for a quote on a Used National Instruments SCXI-1303 Misc. The SCXI-2000 is a general-purpose chassis and is used with current and future SCXI modules. Brand: National Instruments | Category: | Size: 0. The 1303 & 1300 are in essence, the same except for additional thermal compensation circuitry on the 1303 for TC measurements. Unless this is a typo, if you're getting Negative 4mA, your cable is intermittent or your bias voltage is the culprit, such as a bad GND reference or GND loop. Experienced Expert Engineers that. from the SCXI-1300, SCXI-1303, TBX-1303, and TC-2095 terminal blocks. SCXI-1193 National Instruments, NI, SCXI-1193 National Instruments Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. Fax: (240) 376-1381. com ¥ ni. 2 and now my SCXI 1001 with a SCXI 1102 and SCXI 1303 terminal block no longer reads the correct voltage. This National Instruments SCXI-1530 4-Channel Accelerometer Input Module is used and in excellent condition. TBX-68S. The SCXI-1303 has bias resistors for floating signals and pull-up resistors for open TC detection actually socketed into the terminal block. Lookout 3. SCXI Terminal Blocks 3 BUY ONLINE at ni. Thank you for posting on the National Instruments forums.